Contractor Hub

Are you a contractor who works with Heat Pumps, or would you like to become one? Find out how to get certified in Alaska Heat Smart's efficiency programs with our resources below.

Getting Listed as Qualified Contractor

Alaska Heat Smart (AHS) hosts a Qualified Contractor List of heat pump installers and electricians who have the proper licensing, insurance, and certifications to do heat pump installations and wiring. ACES applicants can choose from the Qualified Contractor List or choose a contractor that is not on the list. The ACES program has eligible equipment and contractor reporting requirements regardless if a contractor is on the AHS list or not.

Contractors interested in being on the AHS Qualified Contractor List can reach out to aces@akheatsmart.org. To be included on the list, contractors must have the following:

  • Certificate of Insurance
  • State of Alaska Business License
  • Specialty Licenses
    • Heat pump installers: General Contractor, Mechanical Administrator, Residential Contractor, or Handyman Contractor license
    • Electricians: Electrical Administrator’s License
  • Have completed 20 successful heat pump installations/wirings in the past 5 years
    • Provide two references
  • EPA 608 Certificate, Type II or Universal (heat pump installers only)
    • One member of the installation team must have this certification

Equipment Eligibility

To be eligible for a rebate through the ACES program, heat pumps must meet the following specifications. The cold climate specifications are aligned with the ENERGY STAR cold climate heat pump requirements found here. The specifications below are minimum requirements. We strongly recommend installing a heat pump with higher performance standards that maintains 100% heating capacity at 5°F.

Minimum Cold Climate Requirements
ProductSpecifications
Heat Pump Split Systems (ductless)

– HSPF2 ≥ 8.5
– COP at 5°F ≥ 1.75
– Percent of heating capacity at 5°F ≥ 70% of that at 47°F
– Output capacity that drops below 0°F

Heat Pump Split Systems (ducted)

– HSPF2 ≥ 8.1
– COP at 5°F ≥ 1.75
– Percent of heating capacity at 5°F ≥ 70% of that at 47°F
– Output capacity that drops below 0°F

Other Program Requirements 
  • A whole house surge protector or a heat pump surge protector must be installed by either a heat pump installer, an electrician, or your local electric utility. 
  • A drain pan heater is required in all heat pump installations. 
  • Heat pumps must be protected and registered under the manufacturer’s parts warranty.

If you would like to install an air to water or ground source system, please email the specifications to aces@akheatsmart.org for review.

Download a PDF of the Eligible Equipment Requirements here.